Challenge

Links for Srugical Masks, N95, Respirators etc

Electrospinning Apparatus

System Components & Process Parameters

  • Syringe Pump
    • vol. flow rate: 0.1 - 2 mL/h
  • Emitter (Hypodermic Needle)
    • Gauge: 27G / 21G
    • Preferable flat tip
  • Syringe
    • 5 mL/ 3 mL plastic
    • Luer lock (Do not use needle with slip-on design)
  • DC Voltage Supply
    • Voltage: 0 to 30 kV
    • Current: 0.5 mA to 1.5 mA
    • Note: Request for output cable.Ensure there is an earth terminal on the instrument
  • Emitter Tip to Collector Distance
    • 0 - 12 cm

Syringe Pump