Skip to content
Snippets Groups Projects
Select Git revision
  • d59683d9f5f62867e45a05d8a780b05d624d2ef3
  • master default protected
2 results

README.md

Blame
  • Electrospinning Apparatus

    System Components & Process Parameters

    • Syringe Pump
      • vol. flow rate: 0.1 - 2 mL/h
    • Emitter (Hypodermic Needle)
      • Gauge: 27G / 21G
      • Preferable flat tip
    • Syringe
      • 5 mL/ 3 mL plastic
      • Luer lock (Do not use needle with slip-on design)
    • DC Voltage Supply
      • Voltage: 0 to 30 kV
      • Current: 0.5 mA to 1.5 mA
      • Note: Request for output cable.Ensure there is an earth terminal on the instrument
    • Emitter Tip to Collector Distance
      • 0 - 12 cm

    Syringe Pump